A foundation report can look like a stack of drawings and numbers. Behind it is a fairly simple question: is this foundation performing the way a house on this soil reasonably should? Here is how an engineer gets to an answer, and what the main terms in a report mean.
Every slab moves a little
Houses on clay soil are not expected to stay perfectly still. The Foundation Performance Association's evaluation guideline says plainly that all foundations experience some movement, and that even a well-designed, well-built slab is expected to move differentially. So the engineer is not looking for movement. The engineer is looking for movement large enough, or in a pattern, that matters.
Step one: the elevation survey
The core measurement is a floor-elevation survey. Using a level, the technician records relative heights of the floor at many points through the house. Those readings become a map that shows where the floor is high and where it is low.
Raw readings need interpretation. Different floor coverings change the apparent height, so a careful report adjusts for them. A slab is also never poured perfectly flat, so some unevenness is simply built in. If the original elevations were never recorded, which is usually the case, the engineer cannot subtract them out. Instead, the engineer weighs the survey against other clues, such as brick courses that are out of level, door alignment, and the pattern of cracking. The ASCE Texas Section guidelines specifically caution that a floor survey should not be the only basis for a conclusion.
A single survey is also a snapshot. It shows the shape of the foundation on one day, not whether it is still moving. Repeated surveys over months can show change, which is why monitoring is sometimes the right recommendation.
Deflection and tilt
Two terms show up in most reports:
- Deflection describes how much the floor bows over a span. The deflection ratio compares the largest deviation from a straight line to the length of the span. A foundation that dips or humps across a room or across the house will show a larger ratio than one that is merely sloped.
- Tilt describes a plane that slopes across the foundation, such as one side being lower overall. The ASCE guidelines note that a slope of more than about 1 percent is usually noticeable underfoot.
The ASCE guidelines compare foundation deflection to the L/360 limit that building codes use for floor members, applying it to the foundation as a whole. It is a useful reference point and not a pass-fail test. Per the guidelines, a profile within the limit makes significant deflection unlikely unless visible symptoms say otherwise. A profile beyond the limit with few symptoms calls for more information, while one beyond the limit with clear symptoms usually supports a conclusion that the foundation has deflected excessively. The guidelines also advise caution when reading small areas, because built-in unevenness can dominate over short distances.
Levels A, B and C
Texas engineers commonly describe the depth of an evaluation in three levels, used in both the ASCE Texas Section guidelines and earlier Texas Board of Professional Engineers guidance:
- Level A is a first-impressions review: an interview, a walk-through, and observations.
- Level B adds a review of available documents and a floor-elevation survey, with the analysis written up.
- Level C adds further investigation as needed, which may include plumbing tests, soil sampling, or material testing.
The guidance expects the engineer to recommend the lowest level that adequately answers the question, so a higher level is not automatically better. Ask which level was performed so you can compare two reports fairly.
DeltaPly evaluations follow the ASCE Texas Section guidelines at Level B. In plain terms, that means we review the history of the house and any documents you provide, measure floor elevations throughout, and issue a written, signed and sealed report with the analysis. It is more than a walk-through impression, and it does not automatically include the extra testing a Level C investigation would add, such as plumbing or soil tests, unless those are needed later.
What the recommendations can look like
A report does not have to end in repair. Recommendations can include improving drainage, managing watering, dealing with trees near the house, monitoring, testing plumbing lines, or, where the evidence supports it, structural repair. The ASCE guidelines describe these non-structural measures as a reasonable first approach in some cases.
Who does the work
At DeltaPly Engineering, technicians collect the measurements and document the house under James Otto, P.E.'s direct supervision. James evaluates the findings, and the report is signed and sealed. Texas board rules say an engineer's seal tells the reader that the work was performed or directly supervised by the named engineer. We do not sell repairs, so the recommendation is not tied to a job. If you need a document for a sale, a lender, or a contractor's bid, the report is built for that.
If you already have a contractor's estimate, we are glad to review it against what your foundation is actually doing.
Sources and further reading
- ASCE Texas Section, Guidelines for the Evaluation and Repair of Residential Foundations, Version 3 (2022)
- Foundation Performance Association, Guidelines for the Evaluation of Foundation Movement (FPA-SC-13-1)
- Texas Board of Professional Engineers, Policy Advisory 09-98-A on residential foundations; 22 TAC §137.33, Sealing Procedures
Questions about your own report or a bid you received? Text (972) 921-5721 or use the Contact Us page.
Need a foundation inspection?
Request an Inspection